Sacred Address

Prof. Hamdy Mahfouz Moustafa
 

Prof. and Head of Gastroenterology & Hepatology and Tropical Medicine
 

Faculty of Medicine- Al-Azhar University, Assiut
 

Editor-In-Chief of Al-Azhar Assiut Medical  Journal (AAMJ)

 

Vice President of Al-Azhar Group of Hepatology and Gastroenterology (AGHG)
 

Adress: 7 Borg Aldeaa, Makka street, Ferial, Assiut, Egypt

 

e-mail: dr.hamdymm511@gmail.com

 

AAMJ e-mail: new.aamj@yahoo.com
 

Website: www.aamj.eg.net
 

Mobile: +2  010 06698741
 

            Tel: +2 88 2306132
 

           Deposit No in CIB Bank (Assiut Branch) : 5950001692

Get back to us

  • Your Name
  • Email Address
  • Message
  •  

You are Here:

  • Home
  • Article Details

April 2015 - Volume 13 - Issue 2
Editor-in-Chief: Prof Dr. Hamdy Mahfouz Moustafa ISSN: 1687-1693 Frequency: 4

USEFULLNESS OF COMBINED TESTS FOR ACCURATE DIAGNOSIS OF SPONTANEOUS BACTERIAL PERITONITIS
Asmaa N. Mohammad1, Laila M. Yousef2, And Hamdy S. Mohamed


Publisher:
DOI:

Abstract

BACKGROUND: Spontaneous bacterial peritonitis (SBP) is one of the potentially life-threatening complications in ascetic cirrhotic patients. The improved survival might be explained by a more rapid and accurate diagnosis and treatment. Our aim is to evaluate the combined use of a leucocyte esterase strip together with ascetic fluid lactoferrin antibodies for rapid and accurate diagnosis of spontaneous bacterial peritonitis when compared with standard manual laboratory polymorphonuclear leucocyte counting. METHODS: Non-selected cirrhotic 84 patients undergoing diagnostic paracentesis had an ascitic sample sent for a conventional polymorphonuclear leucocyte count. In addition, a sample was tested with a bedside leucocyte esterase reagent strips, and another sample was tested by Human Lactoferrin, LTF/LF kits detected by Enzyme linked immunosorbent assay (ELISA). RESULTS: Sensitivity of both leucocyte esterase reagent test & lactoferrin antibody test was 0.71 with confidence interval (0.53-0.85). Specificity of both leucocyte esterase reagent test & lactoferrin antibody test was 1.00 with confidence interval (0.93-1.00). Positive predictive value of both leucocyte esterase reagent test & lactoferrin antibody test was 1.00 with confidence interval (0.86-1.00). Negative predictive value of both leucocyte esterase reagent test & lactoferrin antibody test was 0.83 with confidence interval (0.71-0.92). Diagnostic accuracy of combined leucocyte esterase reagent test & lactoferrin antibody test was 0.88 with confidence interval (0.79-0.94). CONCLUTION: Combined use of both leucocyte esterase reagent strips and lactoferrin antibody showed high values of specificity, positive predictive value, negative predictive value and accuracy for leucocyte esterase ≥ +2 and lactoferrin antibody ≥ 83 ng/ml. However, sensitivity decreased.